Melt Pressure Transducers
with Rigid
Stem
features
-
measuring range from 0/10 to 0/2000 bar, accuracy
up to 0.3%FS
-
internal shunt calibration signal of 80 %FS
-
amplified signal output available with zero
and span adjustment
-
hastelloy membrane available on request
-
rigid and compact construction, 100% made from stainless steel
construction with special alloy coating
on pressure diaphragm
|
specifications and
dimensions
| measuring pressure range |
bar |
0/10, 0/20, 0/35, 0/50, 0/70, 0/100, 0/200, 0/350, 0/500, 0/700,
0/1000, 0/1400, 0/2000 |
| overload pressure |
% FS |
150 (2100 bar max.) |
| signal output@FS |
mV/V |
3.33 mV/V |
- amplified signal output |
mA |
4~20 mA |
- amplified signal output |
Vdc |
0~5 Vdc, 0~10
Vdc |
| combined error |
% FS |
0.5 (standard), 0.3, 1.0 |
| repeatability |
% FS |
0.2 |
| output resistance |
Ω |
350 ± 10% |
| load resistance |
Ω |
1000 |
| insulation resistance |
MΩ |
≥ 1000 @ 100 Vdc |
| span adjustment |
% |
± 6 |
| zero adjustment |
% |
± 10 |
| shunt calibration |
%FS |
80 |
power supply |
V dc |
10 (8 ~ 12 acceptable) for MPT of 3.33 mV/V strain gauge output |
| 24 (12~36 acceptable) for MPT of amplified output signal |
| max. temp. at wetted part |
°C |
400 |
| compensated temp. range |
°C |
0 ~80 |
| max. temp. @wetted parts |
°C |
400 |
| temp. effect on ZERO |
%FS/10 °C |
0.5 |
| temp. effect onSPAN |
%FS/10 °C |
0.5 |
| process connection |
to media |
½" -20 UNF-2A (standard),
M14 x 1.5, M18 x 1.5 |
| electrical connection |
pin |
6-pin (standard) male tighten connector, 8-pin male screw in connector
|
| long periods stability |
%FS/year |
<0.15 |
| max mounting torque |
N.m. |
40 |
| net weight |
kg |
~ 0.5 |
MPT Ordering Codes
Back to top
|