P/N
|
characteristics
|
operating temperature
|
application
|
curing conditions
|
shelf-life
|
| B-610 |
high performance epoxy, two components,
fast drying, low viscosity, minimum creep and hysteresis, excellent
repeatability and stability, high insulation over a wide temperature
range |
-270 ~ 370 °C |
excellent bonding of all types of BCM strain
gages and compensation resistors,
specially recommended for use in production
of precision transducers
|
cure: 2 hours at 135 °C under
1 ~ 3 bar pressure
post-cure: 2 hours at 165 °C |
6 months at 24 °C,
12 months at 2 °C
in single component form
|
| B-711 |
cyanoacrylate, high adhesive property, small creep and
hysteresis, easy to handle, elevated temperature and moisture deteriorating
its performance |
moderate temperature range |
bonding of common-used gages and of OIC-series high
elongation gages for short term stress analysis |
3 hours at room temperature ("finger" pressure) |
3 months at 2 °C without direct light and moisture |
| B-712 |
polyacetal, moderate viscosity, easy to dilute, fast
drying, small hysteresis,
good repeatability and stability
|
- 30 ~ 150 °C |
bonding of OCP- and OCA- or OKA-series strain gages |
60 minutes at 80 °C under 1 ~ 2 bar, 2 hours at 160
°C |
6 months at room temperature |
| B-713 |
polyimide, stable performance,
small creep and hysteresis
|
- 30 ~ 60 °C |
bonding of high elongation gages for measurements at
moderate temperatures |
1 hours at 120 o C under 1 ~ 2 bar, 3 hours at 180 °C |
12 months at 2 °C |
| B-601 |
phenolic epoxy, high viscosity, good stability and wide
operating temperature range |
- 60 ~ 250 °C |
bonding of OKG- and ECI-series strain gages at moderate
temperature range |
60 minutes at 80 °C under 1 ~ 3 bar, 2 hours at 160
°C |
8 months at 10 °C |
| B-602 |
phenolic acetal, moderate viscosity, small creep and
hysteresis, good repeatability and stability |
- 30 ~ 80 °C |
bonding of ECH-series strain gages or compensation
resistors, possible to cure without pressure |
cure: 2 hours at 120 °C under
1 ~ 3 bar, or 3 hours at 180 °C
post-cure: 2 hours at 180 °C
|
12 months at room temperature |
| B-603 |
polyurethane, two component, water- and
moisture-proof, mildew resistant and high insulation |
- 30 ~ 60 °C |
1) bonding of ECU-series water-proof gages;
2) protective coating for strain gages and for precision transducers
|
24 hours at room temperature, or 4 hours
at 80 °C |
12 months at room temp. in single compo-nent
form |
| B-611 |
special epoxy, two components,
double composition, no solvent
|
room temperature |
bonding of compensation resistors and gage
terminals, and of strain gages for stress analysis at room temperature
under normal pressure |
24 hours at room temperature |
10 months at room temp. in single compo-nent
form |
| B-612 |
polysulfide rubber, high elongation,
water- and moisture-proof, dry at room temperature
|
- 30 ~ 60 °C |
bonding of OIC-series high elongation strain
gages for measurements at room temperature |
24 ~ 36 hours at room temperature ("finger"
pressure ) |
10 months at room temp. in single compo-nent
form |
| B-613 |
silicone rubber, dry at room temperature, water- and
moisture-proof, mildew resistant and high insulation |
- 30 ~ 100 °C |
protective coating or sealant for transducers, and for
strain gages used in stress analysis |
16 ~ 24 hours at room temperature and normal pressure |
12 months at room temperature |